Search results for "radiation exposure"
showing 10 items of 40 documents
Exposure to environmental radionuclides is associated with altered metabolic and immunity pathways in a wild rodent
2019
Wildlife inhabiting environments contaminated by radionuclides face putative detrimental effects of exposure to ionizing radiation, with biomarkers such as an increase in DNA damage and/or oxidative stress commonly associated with radiation exposure. To examine the effects of exposure to radiation on gene expression in wildlife, we conducted a de novo RNA sequencing study of liver and spleen tissues from a rodent, the bank vole Myodes glareolus. Bank voles were collected from the Chernobyl Exclusion Zone (CEZ), where animals were exposed to elevated levels of radionuclides, and from uncontaminated areas near Kyiv, Ukraine. Counter to expectations, we did not observe a strong DNA damage resp…
Ionizing radiation from Chernobyl affects development of wild carrot plants.
2016
AbstractRadioactivity released from disasters like Chernobyl and Fukushima is a global hazard and a threat to exposed biota. To minimize the deleterious effects of stressors organisms adopt various strategies. Plants, for example, may delay germination or stay dormant during stressful periods. However, an intense stress may halt germination or heavily affect various developmental stages and select for life history changes. Here, we test for the consequence of exposure to ionizing radiation on plant development. We conducted a common garden experiment in an uncontaminated greenhouse using 660 seeds originating from 33 wild carrots (Daucus carota) collected near the Chernobyl nuclear power pl…
Reliability and validity of the Digigraph 100 in orthodontic diagnosis.
2001
Cephalometric analyses of lateral cephalograms allow important statements to be made on diagnosis and treatment planning. Such radiographs should, however, be taken with a considerable reduction in radiation exposure. With the Digigraph 100 (Dolphin Imaging Systems Inc., USA) a cephalometric technique based on distance measurements of emitted sonic signals is now available. This study was aimed at determining the degree to which this procedure can cope with the requirements of reliability and validity in the field of orthodontics. For this purpose 50 volunteers were examined by conventional cephalometry with manual tracing of lateral cephalograms as well as by sonic cephalometry, with Jarab…
Estimated radiation exposure of German commercial airline cabin crew in the years 1960-2003 modeled using dose registry data for 2004-2015.
2016
Exposure to ionizing radiation of cosmic origin is an occupational risk factor in commercial aircrew. In a historic cohort of 26,774 German aircrew, radiation exposure was previously estimated only for cockpit crew using a job-exposure matrix (JEM). Here, a new method for retrospectively estimating cabin crew dose is developed. The German Federal Radiation Registry (SSR) documents individual monthly effective doses for all aircrew. SSR-provided doses on 12,941 aircrew from 2004 to 2015 were used to model cabin crew dose as a function of age, sex, job category, solar activity, and male pilots' dose; the mean annual effective dose was 2.25 mSv (range 0.01–6.39 mSv). In addition to an inverse …
Complete written/oral information about dose exposure in CT: is it really useful to guarantee the patients' awareness about radiation risks?
2018
Aims and objectives: According to the European directive 2013/59/Euratom, starting from February 2018, the information relating to patient exposure will be part of computed tomography (CT) reports, but the impact of this information on patients has not been deeply evaluated. Aim of our study was to evaluate patients’ perception of radiation exposure related to routine CT and their understanding after communication of their dose exposure. Materials and methods: A survey, investigating patient’s knowledge of radiation dose, was given to all adult patients (> 18 years) undergoing a CT examination both before and after CT scan. The first survey was the same for all patients. After CT scan, a se…
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
2013
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…
Long-term radiation exposure in patients undergoing EVAR: Reflecting clinical day-to-day practice to assess realistic radiation burden.
2018
Endovascular repair of aortic aneurysms (EVAR) has become an established treatment option currently applied in an increasing numbers of patients with aortic aneurysms. Advantages include reduced surgical trauma, procedural time, intensive care unit and hospital lengths of stay, blood loss as well as morbidity and mortality.The optimal imaging modalities in EVAR follow-up as well as the appropriate intervals between these follow-ups remain subject of controversial discussion. Objective of this study was the evaluation of the realistic radiation exposure and risk estimate postop EVAR treatment.Of the follow-ups required according to the surveillance schedule during the first year post-EVAR, o…
CT exposure in adult and paediatric patients: a review of the mechanisms of damage, relative dose and consequent possible risks.
2014
An increase has been observed not only in the absolute number of CT examinations but also in the length of coverage and number of scanning phases, with the result that exposure to ionising radiation from CT is becoming an increasingly serious problem. The extent of the problem is not entirely known and cannot be adequately addressed without proper knowledge of all the phases that leads to the effective dose calculation. In light of the growing awareness of the issue of ionising radiation dose and the possible risk for the individual and the population, there is a need for radiologists, medical physicists and radiographers to play an active role in dose management. In this review, the author…
Endovascular Embolization of a Large High-Flow Splenic Arteriovenous Fistula and Aneurysm Using the Amplatzer Vascular Plug II.
2015
We describe the use of an Amplatzer Vascular Plug (AVP) II for embolizing a large high-flow splenic arteriovenous fistula and an aneurysm in a young patient. This patient presented to our center with persistent mild abdominal discomfort, 5 years after open splenectomy. Contrast-enhanced computed tomography angiography showed the presence of a fistula between the splenic arterial and splenic venous remnants and a resultant fusiform aneurysmal dilatation of the residual splenic vein. We decide to embolize the splenic artery with a 12-mm diameter AVP II with an oversizing by 70% of the vessel diameter. Celiac angiography performed 5 min postembolization revealed complete obliteration of the sp…
Italian inter-society expert panel position on radiological exposure in Neonatal Intensive Care Units.
2020
Abstract Background In the recent years, clinical progress and better medical assistance for pregnant women, together with the introduction of new complex technologies, has improved the survival of preterm infants. However, this result requires frequent radiological investigations mostly represented by thoracic and abdominal radiographs in incubators. This document was elaborated by an expert panel Italian inter-society working group (Radiologists, Paediatricians, Medical Physicists) with the aim to assist healthcare practitioners in taking choices involving radiation exposures of new-born infants and to provide practical recommendations about justification and optimization in Neonatal Inte…